Welcome: AOB Digital Energy Technology(Nan Jing) Co., Ltd
Language: Chinese ∷  English
Your location: Home > News

News

10 Leading Causes of UPS Battery Damage

Uninterruptible power supplies (UPS) are used to protect critical equipment from power outages and disturbances. The batteries in a UPS are essential for providing backup power during these events. However, UPS batteries can be damaged by a number of factors, which can shorten their lifespan and reduce their performance.

Here are the 10 leading causes of UPS battery damage:

Overcharging: Overcharging is one of the most common causes of UPS battery damage. It occurs when the battery is charged at a voltage or current that is too high. Overcharging can cause the battery to overheat, which can lead to sulfation, loss of capacity, and even explosion.
Undercharging: Undercharging is another common cause of UPS battery damage. It occurs when the battery is not charged for a sufficient period of time. Undercharging can cause the battery to sulfate, which can lead to a loss of capacity and premature failure.
High temperatures: High temperatures can also damage UPS batteries. Batteries should be stored and operated in a cool, dry environment. Heat can cause the battery to lose capacity and shorten its lifespan.
Low temperatures: Low temperatures can also damage UPS batteries. Batteries should not be stored or operated in freezing temperatures. Cold temperatures can cause the battery to lose capacity and shorten its lifespan.
Vibration: Vibration can also damage UPS batteries. Batteries should be protected from vibration, which can cause the plates to break down and the battery to lose capacity.
Sulfation: Sulfation is a process that occurs when lead sulfate crystals form on the battery plates. Sulfation can be caused by overcharging, undercharging, or high temperatures. Sulfation can lead to a loss of capacity and premature failure.
Corrosion: Corrosion can also damage UPS batteries. Corrosion can be caused by exposure to moisture, chemicals, or fumes. Corrosion can damage the battery terminals and lead to a loss of capacity.
Physical damage: Physical damage can also damage UPS batteries. Batteries should be protected from physical damage, such as dropping or bumping. Physical damage can cause the battery to leak, lose capacity, or even explode.
Age: Age is also a factor in UPS battery damage. Batteries have a limited lifespan and will eventually need to be replaced. The average lifespan of a UPS battery is 3-5 years.
Improper maintenance: Improper maintenance can also damage UPS batteries. Batteries should be regularly inspected and maintained to ensure that they are in good condition. Improper maintenance can lead to sulfation, corrosion, and other problems.
By understanding the leading causes of UPS battery damage, you can take steps to prevent it. By following the tips in this article, you can extend the lifespan of your UPS batteries and ensure that they are always ready to provide backup power when you need it most.

CATEGORIES

CONTACT US

Contact: Albert Shu

Phone: 19710409880

Tel: 400-1177-032

Email: 19710409880@139.com

Add: Room A781, No. 2 Dingjiashan Road, Dachang Street, Jiangbei New District, Nanjing City, Jiangsu Province, China